Plc 5 1/2 Slot Addressing
This board is for PLC Related Q&A ONLY. Please DON'T use it for advertising, etc. |
- Plc 5 1/2 Slot Addressing Machine
- Plc 5 1/2 Slot Addressing Tool
- Plc 5 1/2 Slot Addressing Machines
- Plc 5 1/2 Slot Addressing System
This course is a complete PLC programming class with step by step instructions on RSLogix & Studio 5000 development. Topics covering hardware, software, ladder logic & everything you need to be a fully competent PLC programmer. With 4 off and 5 on, every slot equals a group (1-slot addressing). When 4 is on and 5 is off, every 1/2 slot equals a group. (1/2 slot addressing) — Both switches ON is an invalid setting.
'Block transfer Write/read, PLC-5 (Ab)'
New Here? Please read this important info!!!- Addressing Reference 1785 PLC-5 6 Figure 5 shows how to address the status file of the PLC-5 data table. Figure 6 shows a word of the status file. Figure 5 shows what is stored in each word of the status file. For more information, refer to the PLC-5 Programming Software Configuration and Maintenance Manual, publication 6200-6.4.6.
- Write the address based input for the signal connected to terminal 5 of the input module in slot 2 I: 2.0/5 RLL control connects input contacts and output actuators in an electrical circuit to the process.
- The PLC-5 and SLC-500 use a rack/slot/register/bit method for addressing the I/O modules. For example input point 15 in slot 2 of rack 1 would be addressed - I:1:2/15. The same goes for outputs. Now the legacy problems prop up. In the old days most things were octal so AB allows for different methods for addressing modules in the rack.
Email this topic to a friend Printer-friendly version of this topic | Archived thread - Read only Previous Topic Next Topic | ||
HomeConferences*** LIVE PLC Q&A ***(Public) | |||
---|---|---|---|
Original message |
Mike - (9 posts) | Jan-22-02, 12:27 PM (EST) |
'Block transfer Write/read, PLC-5 (Ab)' | |
Basically, I need to know what the specifics are of the BTW/BTR in a PLC-5. I am new to these functions, and need to appreciate the interpolation between the control bits BTxxxx and the remote I/O attached. I have tried unsuccessfully to get a decent explanation from Ab.com, and the programming help is of little use. If anybody can help me thanks v much. | |
Top |
Table of contents |
RE: Block transfer Write/read, PLC-..., Allen Nelson, Jan-22-02, (1) RE: Block transfer Write/read, PLC-..., ianingram, Jan-23-02, (2) |
Lobby Topics Previous Topic Next Topic |
Messages in this topic |
Allen Nelson - (187 posts) | Jan-22-02, 01:49 PM (EST) |
1. 'RE: Block transfer Write/read, PLC-5 (Ab)' | |
| |
Top |
ianingram - (23 posts) | Jan-23-02, 07:12 AM (EST) |
2. 'RE: Block transfer Write/read, PLC-5 (Ab)' | |
try this link | |
Top |
Remove | Lobby Topics Previous Topic Next Topic |
Rate this topic (1=skip it, 10=must read)? [ 1 2 3 4 5 6 7 8 9 10 ] |
Your Personal PLC Tutor Site Learn Now!!. |
There are a number of addressing schemes used by PLC manufacturers. Let’s take a quick look at how memory locations (including hardware I/O) are accessed with RSLogix 500. Along the way, let’s define some terms.
INSTRUCTION – RSLogix’s command language is comprised of “instructions”. An XIC (it looks like a normally open contact –] [– ) is an instruction. A timer is an instruction. A few of the most common instructions are described below.
BIT – an address within the PLC. It can be an input, output or internal coil, among others.
In RSLogix, there are a couple of ways to show the address of a bit. The default is:
Plc 5 1/2 Slot Addressing Machine
[type]:[word]/[bit]
For example, an address that references an output of a MicroLogix 1100 is O:0/0. That is:
O:0/5 means that it is a physical output.
O:0/5 means that it uses Slot 0 (in the case of the 1100, this output is onboard)
O:0/5 means that it is the fifth output on the PLC.
By the way, don’t get the capital “O” confused with a zero.
RUNG – A section of the PLC ladder program that terminates in an output function of some type. Just like in an electrical ladder diagram, a rung has some type of output that is turned on or turned off by the preceding entities in the rung. The first rung in a ladder program is always 0000.
HARDWIRED INPUT – a physical connection to the PLC from an input device (switch or sensor, etc.).
Plc 5 1/2 Slot Addressing Tool
Allen-Bradley uses the capital letter “I” to designate a hardwired input. An address that describes an input on an SLC 500 is I:4/0.
Similar to the output structure,
I:4/0 means that it is a physical input.
I:4/0 means that it uses Slot 4 (the 5th slot in the rack).
I:4/0 means that it is the first input on the card.
Don’t get the capital “I’s” confused with ones.
HARDWIRED OUTPUT – a physical connection from the PLC to an output device (relay or pilot light, etc.) As was said above, an address that references an output of an SLC 500 is O:5/0.
INTERNAL COIL
This is a programmable bit used to simulate a relay within the PLC. The internal coil has no connection to the outside world. It does not connect to an output card. Internal coils are used to store information. The “contacts” of this “relay” can then be used multiple times in other parts of the program.
In RSLogix, the “B3” (binary) file is commonly used for all the internal coils. There are many other words in other files that have bits you can use as internal coils, but we are going to stick with the B3 file for our application.
B3:0/0 means that it references an internal Binary file
B3:0/0 means that it uses the first word in the table
B3:0/0 means that it is the first bit in the word.
Note that, unlike the Output and Input files, you have to use the file number in the address. In this case, the default file number is 3.
TIMER
A timer is a programmable instruction that lets you turn on or turn off bits after a preset time.
The two primary types of timers are TON for “timer on delay” and TOF for “timer off delay”.
Timers in A-B SLC and MicroLogix processors use file 4 for their timers.
T4:0 means that it references an internal Timer file
T4:0 means that it uses the first timer in the table
The address T4:0 simply refers to the timer. Each timer has bits that turn on after the timing function is complete. You can address this bit by simply putting a “/DN” after the timer address. DN stands for “done”.
For example, if timer T4:0 is a TON (timer on delay), then the bit T4:0/DN will turn on after the timer has reached its preset value.
COUNTER
A counter is a programmable instruction that lets you turn on or turn off bits after a preset count has been reached.
There are different types of counters available in the RSLogix, but the CTU (counter up) instruction covers everything we will talk about here.
Counters in A-B SLC and MicroLogix processors use file 5.
C5:0 means that it references an internal Counter file
C5:0 means that it uses the first counter in the table
The address C5:0 simply refers to the counter. Each counter has bits that turn on after the counting function is complete. You can address this bit by simply putting a “/DN” after the counter address. DN stands for “done”.
Plc 5 1/2 Slot Addressing Machines
For example, if counter C5:0 is a CTU (counter up), then the bit C5:0/DN will turn on after the counter has reached its preset value.
–] [– Normally Open Contact
When used with a hardwired input, this instruction is off until there is a voltage applied to the input. The bit address then goes high, or on, and the instruction becomes “true.” It works the same way when it has the same address as an internal coil, except that the coil must be turned on by logic in the program.
Plc 5 1/2 Slot Addressing System
Allen-Bradley calls these normally open contacts “XIC”, or “eXamine If Closed” instruction.
An XIC instruction can reference a hardwired input, a hardwired output, an internal coil or a timer done bit, among others.
–]/[– Normally Closed Contact
This is an inverted normally open contact.
When used with a hardwired input, this instruction is “true” until there is a voltage applied to the input. It then goes low, or off, and becomes “false.”
It also can be used with an internal coil, becoming true when the coil is off and becoming false when the coil is on.
Allen-Bradley calls these normally closed contacts “XIO”, or “eXamine If Open” instructions.
-( )- Output Coil
When used with a hardwired output, this function is off until the logic in the program allows it to turn on. It then becomes “true”, and will energize the device that is wired to the respective output.
If it is used as an internal coil, it will toggle the instructions associated with it. That is, it will close a normally open instruction and open a normally closed instruction.
Allen-Bradley calls these outputs “OTE”, or “OutpuT Energize”.
An OTE may be used with a hardwired output or an internal coil.
TRUE – A state that indicates an instruction is allowing logic to “flow” through it.
Also, if the logic in a rung turns on the output of the rung, then the rung is said to be true.
FALSE – Without stating the obvious, this is the opposite of true.
Excerpted from PLC Programming with RSLogix 500